Productos
- Regulador de presión
- Amplificador de caudal volumétrico
- regulador de presión proporcional
- Regulación de caudal volumétrico
- Válvulas limitadoras de presión
- Presostato
- Transmisor de presión
- Dispositivos para la medición de presión
- Dispositivos de acero inoxidable
- Tratamiento de aire
- Aumentador de presión
- Componentes de protección
Create offers directly in the shop and download them!
You have added items to your personal offer.
To download your offer, please log in with your access data in the shop.
You will automatically be deducted the deposited discounts.
Don't have a customer account yet?
No problem, register as a new customer or download your offer as a guest.
Benefits of a customer account:
- Your discounts are displayed automatically
- Overview of all offers
New Customer Login Download as a guest Back
Please fill out the following form to start the download
PQ2
Seleccione una variante del artÃculo en la tabla de la vista general más abajo.
Descripción:
The pneumatic proportional valve produces outlet pressure in
proportion to an electrical command input signal. It comprises
a complete closed loop servo system consisting of valves,
manifold, housing and electronic controls.
Double_loop:
The servo valve expands in single loop operation by combining
an additional feedback from an external sensing device with the
internal transducer. The external sensor provides information
on the control status.
The PQ2 then compares the command signal with the second loop
feedback signal. Should there be a difference in the signal
comparisons, the servo valve will make adjustments to the
internal loop to bring the system into balance. This provides
accurate final outlet. The acceptance of electrical feedback from
an external sensor enables precise control of conditions such as
pressure, force, torque, position or flow.
External_pressure_transducer:
Any pressure transducer for 0-10 V and 4-20 mA output signal and
suitable for 15-24V DC supply voltage can be applied.
An appropriate coupling socket plus cable is required.
Supply_voltage: 15...24 V DC, residual ripple < 10%, with reverse voltage protection
Command signal: 0-10V, 4-20mA as an option